SealSafe

SealSafe InstaSet B-200
1 coat application using the HVLP2000 sprayer

SealSafe S-200
Excellent elongation and bond. Used in constant ponding environments.

SealSafe A-205
Colored options. Excellent elongation and Solar reflective.

SealSafe PU-100
Excellent durability. Solar reflective waterproof coating.
SealSafe InstaSet B-200








SealSafe S-200








SealSafe A-205








SealSafe PU-100




Benefits
1. Seamless and durable waterproof membrane that easily conforms to various shapes, without cutting and fitting (as is necessary with sheet products).
2. Withstands ponding water.
3. Superior adhesion to most substrates.
4. Long term UV stability.
5. Resistant to salts, acids, and various chemicals.
6. Water based, no solvents, and VOC free.
7. Excellent elongation, recovery, and flexibility for crack bridging and to withstand thermal cycling.
8. No open flame or kettle required.
9. Expensive application equipment is not critical.
Coverage
-
Vertical Surfaces
Apply a minimum final thickness of 1 gallon per 34.6 sq ft (3.2 sq/m). It should require around 3-4 heavy coats to achieve a 30 mil (0.76mm) (DFT) membrane.
-
Flat/Ponding Surfaces
Apply a minimum final thickness of 1 gallon per 17.3 sq ft (1.6 sq/m). It should require around 3-4 heavy coats to achieve a 60 mil (1.5mm) (DFT) membrane.
-
Vertical Surfaces
Apply a minimum final thickness of 1 gallon per 32 sq ft (2.9 sq/m). It should require around 3-4 heavy coats to achieve a 30 mil (0.76mm) (DFT) membrane.
-
Flat/Ponding surfaces
Apply a minimum final thickness of 1 gallon per 16 sq ft (1.4 sq/m). It should require around 3-4 heavy coats to achieve a 60 mil (1.5mm) (DFT) membrane.
-
Vertical Surfaces
Apply a minimum final thickness of 1 gallon per 25 sq ft (2.3 sq/m). It should require around 3-4 heavy coats to achieve a 30 mil (0.76mm) (DFT) membrane.
-
Flat/Ponding surfaces
Apply a minimum final thickness of 1 gallon per 12.5 sq ft (1.16 sq/m). It should require around 3-4 heavy coats to achieve a 60 mil (1.5mm) (DFT) membrane.
-
Vertical Surfaces
Apply a minimum final thickness of 1 gallon per 34.5 sq ft (3.2 sq/m). It should require around 3-4 heavy coats to achieve a 20 mil (0.76mm) (DFT) membrane.
-
Flat/Ponding surfaces
Apply a minimum final thickness of 1 gallon per 17.25 sq ft (1.6 sq/m). It should require around 4-5 heavy coats to achieve a 40 mil (1.5mm) (DFT) membrane.
Typical Substrates
- Flat Roofs
- Metal Roofs
- Large Water Features
- Concrete Infrastructure
- Flat Roofs
- Metal Roofs
- Ponds
- Above Grade, Non-Traffic Area's
- Flat Roofs
- Metal Roofs
- Ponds
- Above Grade, Non-Traffic Area's
- Flat Roofs
- Metal Roofs
- Walls
- Low Traffic Area's
Documents
Flat Roof General Application Guideline
-
SealSafe InstaSet B-200
read the data sheet -
SealSafe InstaSet B-200
read the sds
-
SealSafe S-200
read the data sheet -
SealSafe S-200
read the sds
-
SealSafe A-205
read the data sheet -
SealSafe A-205
read the sds
-
SealSafe PU-100
read the data sheet -
SealSafe PU-100
read the sds