108,000 sq. ft. Pre-Cast Concrete at Landfill Site, Hamilton

To apply a chemical resistant coating to precast concrete pieces that were subjected to sulphuric acid and hydrogen sulphide gas. Liquid Rubber MetalSafe InstaSet B-300 was spray applied with our HVLP2000 at a thickness of 80 mil or 2 mm, to over 10,000 square meters of precast concrete. The HVLP2000 instant set system allowed for the entire membrane thickness to be applied in one pass resulting in  minimal downtime and a quick turnaround for the project.